Dakota Quad Cab 4WD V6-3.9L VIN X (2001)
Alternator: Service and Repair
Generator Replacement
REMOVAL
WARNING: DISCONNECT NEGATIVE CABLE FROM BATTERY BEFORE REMOVING BATTERY OUTPUT WIRE (B+ WIRE)
FROM GENERATOR. FAILURE TO DO SO CAN RESULT IN INJURY OR DAMAGE TO ELECTRICAL SYSTEM.
1. Disconnect negative battery cable at battery.
2. Remove generator drive belt. Refer to Cooling System for procedures.
3. Unsnap plastic cable protector cover from B+ mounting stud.
Fig.3 Remove/Install Generator
4. For These Engines: Remove generator pivot and mounting bolts/nut (Fig. 3). Position generator for access to wire connectors.
Fig.5 Generator Connectors - Typical Bosch