dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Generator Replacement|Page 4789 > < Electrical Specifications|Page 4786
Page 1
background image

Alternator: Service and Repair
Generator Replacement

REMOVAL

WARNING:  DISCONNECT NEGATIVE CABLE FROM BATTERY BEFORE REMOVING BATTERY OUTPUT WIRE (B+ WIRE)
FROM GENERATOR. FAILURE TO DO SO CAN RESULT IN INJURY OR DAMAGE TO ELECTRICAL SYSTEM.

1. Disconnect negative battery cable at battery.
2. Remove generator drive belt. Refer to Cooling System for procedures.
3. Unsnap plastic cable protector cover from B+ mounting stud.

Fig.3 Remove/Install Generator

4. For These Engines: Remove generator pivot and mounting bolts/nut (Fig. 3). Position generator for access to wire connectors.

Fig.5 Generator Connectors - Typical Bosch

Generator Replacement|Page 4789 > < Electrical Specifications|Page 4786