dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Water Pump|Specifications|Page 1571 > < Water Pump|Specifications|Page 1569
Page 1
background image

Water Pump: Service and Repair

WATER PUMP-3.9L/5.2L/5.9L ENGINES 

REMOVAL 
The water pump can be removed and installed without discharging the air conditioning system (if equipped).
1. Disconnect battery negative cable.
2. Drain cooling system. Refer to Draining and Filling found under Cooling System, Service and Repair.
3. Do not waste reusable coolant. If solution is clean, drain coolant into a clean container for reuse.

WARNING:  CONSTANT TENSION HOSE CLAMPS ARE USED ON MOST COOLING SYSTEM HOSES. WHEN REMOVING OR
INSTALLING, USE ONLY TOOLS DESIGNED FOR SERVICING THIS TYPE OF CLAMP, SUCH AS SPECIAL CLAMP TOOL
(NUMBER 6094). SNAP-ON CLAMP TOOL (NUMBER HPC-20) MAY BE USED FOR LARGER CLAMPS. ALWAYS WEAR
SAFETY GLASSES WHEN SERVICING CONSTANT TENSION CLAMPS.
 

CAUTION:  A number or letter is stamped into the tongue of constant tension clamps. If replacement is necessary, use only an original equipment
clamp with matching number or letter. 

4. Remove upper radiator hose clamp and hose at radiator.

Fan Blade And Viscous Fan Drive -3.9L/5.2L/5.9L Engines

5. The thermal viscous fan drive is attached (threaded) to the water pump hub shaft. Remove fan/viscous fan drive assembly from water pump by

turning mounting nut counterclockwise as viewed from front. Threads on viscous fan drive are RIGHT HAND. A Snap-On 36 MM Fan Wrench
(number SP346 from Snap-On Cummins Diesel Tool Set number 2017DSP) can be used. Place a bar or screwdriver between water pump pulley
bolts to prevent pulley from rotating. Do not attempt to remove fan/viscous fan drive assembly from vehicle at this time.

6. If water pump is being replaced, do not unbolt fan blade assembly from thermal viscous fan drive.
7. Remove fan shroud attaching hardware (two bolts at bottom-two clips at top).
8. Remove fan shroud and fan blade/viscous fan drive assembly from vehicle as a complete unit.
9. After removing fan blade/viscous fan drive assembly, do not place thermal viscous fan drive in horizontal position. If stored horizontally, silicone

fluid in viscous fan drive could drain into its bearing assembly and contaminate lubricant.

10. Do not remove water pump pulley bolts at this time.

Water Pump|Specifications|Page 1571 > < Water Pump|Specifications|Page 1569