dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Positive Crankcase Ventilation Valve|Testing and Inspection|Page 2641 > < Crankcase Filter|Description and Operation
Page 1
background image

Positive Crankcase Ventilation Valve: Testing and Inspection

Vacuum Check At PCV Valve - Typical

1. With engine idling, remove the PCV valve from cylinder head (valve) cover. If the valve is not plugged, a hissing noise will be heard as air passes

through the valve. Also, a strong vacuum should be felt at the valve inlet.

Vacuum Check At Valve Cover Opening

2. Return the PCV valve into the valve cover. Remove the fitting and air hose at the opposite valve cover. Loosely hold a piece of stiff paper, such as

a parts tag, over the opening (rubber grommet) at the valve cover.

3. The paper should be drawn against the opening in the valve cover with noticeable force. This will be after allowing approximately one minute for

crankcase pressure to reduce.

Positive Crankcase Ventilation Valve|Testing and Inspection|Page 2641 > < Crankcase Filter|Description and Operation