dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Bosch Alternators|Page 2680 > < Bosch Alternators|Page 2678
Page 1
background image

Generator: Testing and Inspection
Chrysler Alternators

Charging Circuit Resistance Test

Fig. 6 Charging circuit resistance test. 1985---88 units w/regulator in engine electronics

UNITS W/REGULATOR IN-ENGINE ELECTRONICS

1.

Disconnect battery ground cable and the "Bat" lead from alternator output terminal.

2.

Complete test connections as shown.

3.

Remove air hose between power module and air cleaner, then the wiring harness electrical connector.

4.

Connect a suitable jumper wire from wiring harness connector green wire terminal to ground. Do not connect blue J2 lead of wiring electrical
connector to ground.

5.

Connect battery ground cable, then start engine and operate at idle.

6.

Adjust engine speed and carbon pile rheostat to obtain 20 amps in the circuit and check voltmeter reading. Reading should not exceed .5 volts. If a
higher voltage drop is indicated, inspect, clean and tighten all connections in the circuit. A voltage drop test at each connection can be performed
to isolate the problem.

Current Output Test

Bosch Alternators|Page 2680 > < Bosch Alternators|Page 2678