All Other Service Bulletins for Coolant Temperature Sensor/Switch (For Computer): > < Air Cleaner Housing - Oil Leaking From The Housing|Page 1338
Page 3
background image

FIGURE 2

7.

Remove the crankcase vent to air cleaner tube assembly, PCV valve and intake manifold hose assembly (Figure 2). Remove the air cleaner and
breather elements and discard. Clean any oil from the air cleaner housing and PCV system. Install new filter and breather elements in the air
cleaner.

8.

Reinstall valve cover on engine using procedure in the service manual. Allow two to three hours for the RTV to cure before starting the engine.

9.

Reinstall clean PCV system.

POLICY:

Reimbursable within the provisions of the warranty

TIME ALLOWANCE:
Labor Operation No.

09-35-20-90 . . . . . . . . 1.0 Hrs.

FAILURE CODE:

65 - Leaks