Durango 2WD V8-4.7L Flex Fuel (2009)
1. Position the blend door actuator (1) to the bottom of the HVAC housing (2). If necessary, rotate the actuator slightly to align the splines on the
actuator output shaft (3) with those on the blend-air door linkage (4).
2. Install the three screws (1) that secure the blend door actuator and cover (2) to the bottom of the HVAC housing (3). Tighten the screws to 2 Nm
(17 in. lbs.).
3. Connect the HVAC wire harness connector (1) to the blend door actuator. Make sure the wire harness is properly secured to the bottom of the
HVAC housing.
4. Reconnect the negative battery cable.
5. Initiate the Actuator Calibration function using a scan tool See: Testing and Inspection/Component Tests and General Diagnostics/HVAC System
Test.
Rear
INSTALLATION