dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Hazard Warning Switch > < Hazard Warning Flasher|Locations|Page 7646
Page 1
background image

Hazard Warning Flasher: Service and Repair

REMOVAL

WARNING:  ON VEHICLES EQUIPPED WITH AIRBAGS, DISABLE THE AIRBAG SYSTEM BEFORE ATTEMPTING ANY
STEERING WHEEL, STEERING COLUMN, SEAT BELT TENSIONER, OR INSTRUMENT PANEL COMPONENT DIAGNOSIS OR
SERVICE. DISCONNECT AND ISOLATE THE BATTERY NEGATIVE (GROUND) CABLE, THEN WAIT TWO MINUTES FOR THE
AIRBAG SYSTEM CAPACITOR TO DISCHARGE BEFORE PERFORMING FURTHER DIAGNOSIS OR SERVICE. THIS IS THE
ONLY SURE WAY TO DISABLE THE AIRBAG SYSTEM. FAILURE TO TAKE THE PROPER PRECAUTIONS COULD RESULT IN
ACCIDENTAL AIRBAG DEPLOYMENT AND POSSIBLE PERSONAL INJURY.

1. Disconnect and isolate the battery negative cable.

Fig. 5 Combination Flasher

2. Reach under the outboard side of the steering column opening in the instrument panel to access the instrument panel wire harness connector for the

combination flasher located on a mounting tab on the back of the instrument panel armature.

3. Grasp the combination flasher and connector firmly and pull them toward the dash panel to disengage the connector from the mounting tab on the

instrument panel armature.

4. Remove the combination flasher from the instrument panel wire harness connector.

INSTALLATION

WARNING:  ON VEHICLES EQUIPPED WITH AIRBAGS, DISABLE THE AIRBAG SYSTEM BEFORE ATTEMPTING ANY
STEERING WHEEL, STEERING COLUMN, SEAT BELT TENSIONER, OR INSTRUMENT PANEL COMPONENT DIAGNOSIS OR
SERVICE. DISCONNECT AND ISOLATE THE BATTERY NEGATIVE (GROUND) CABLE, THEN WAIT TWO MINUTES FOR THE
AIRBAG SYSTEM CAPACITOR TO DISCHARGE BEFORE PERFORMING FURTHER DIAGNOSIS OR SERVICE. THIS IS THE
ONLY SURE WAY TO DISABLE THE AIRBAG SYSTEM. FAILURE TO TAKE THE PROPER PRECAUTIONS COULD RESULT IN
ACCIDENTAL AIRBAG DEPLOYMENT AND POSSIBLE PERSONAL INJURY.

1. Position the combination flasher to the instrument panel wire harness connector.
2. Align the combination flasher terminals with the terminal cavities in the instrument panel wire harness connector.
3. Using hand pressure, push in firmly on the combination flasher until the terminals are fully seated in the terminal cavities in the instrument panel

wire harness connector.

4. Align the slot in the combination flasher connector with the mounting tab on the instrument panel armature.
5. Using hand pressure, push the combination flasher connector firmly onto the mounting tab until it is fully engaged in the slot.
6. Reconnect the battery negative cable.

Hazard Warning Switch > < Hazard Warning Flasher|Locations|Page 7646