dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Procedures|Page 2531 > < Procedures|Page 2529
Page 5
background image

WARNING: On vehicles equipped with the high voltage system, you must thoroughly read and follow all High Voltage Safety procedures. In

addition, before performing any diagnostic or service procedure near a high voltage component, you must perform the High
Voltage Power Down. Failure to follow these instructions may result in possible serious or fatal injury 
See: Hybrid Drive
Systems/Battery System, Hybrid Drive/Service Precautions 

1. Perform HEV specific high voltage power down and high voltage isolation check safety procedures.  See: Hybrid Drive Systems/Battery System,

Hybrid Drive/Service and Repair/Battery System - High Voltage Power Down

2. Disconnect the negative battery cable.

CAUTION: Disconnecting the 12 V battery from the vehicle within two minutes of the last ignition key transition from Off to Run may cause a

Battery Pack Control Module (BPCM) State Of Charge (SOC) mismatch.

3. Raise and support the vehicle.
4. Drain the TPIM cooling system   See: Cooling System/Service and Repair/TPIM Cooling System Draining
5. Disconnect the coolant pump electrical connector (1).
6. Remove the coolant line (3).
7. Remove the coolant line (5).

8. Remove the coolant pump mounting bolts (2).
9. Remove the coolant pump and bracket (1) from the vehicle.

TPIM Coolant Pump - Installation

TPIM COOLANT PUMP

Procedures|Page 2531 > < Procedures|Page 2529