Durango 2WD V8-5.7L Hybrid (2009)
Drive Motor Power Relay: Service and Repair
High Voltage Negative Contactor - Removal
REMOVAL
WARNING: On vehicles equipped with the high voltage system, you must thoroughly read and follow all High Voltage Safety procedures. In
addition, before performing any diagnostic or service procedure near a high voltage component, you must perform the High
Voltage Power Down. Failure to follow these instructions may result in possible serious or fatal injury See: Battery System, Hybrid
Drive/Service Precautions
WARNING: Once the battery cover is removed from the battery, high voltage is still present in the system even with the service disconnect
removed. When performing any diagnostic or service procedures, use extreme care with tools and other test equipment around
unisolated terminals and wires. Failure to take proper precaution could result in serious or fatal injury.
1. Remove the high voltage battery cover See: Battery System, Hybrid Drive/Hybrid Battery Cover/Service and Repair/High Voltage Battery Cover -
Removal.
2. Remove the fan shroud (1).
3. Remove the push pin (1) and remove the air duct (2).