dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Controls - Front|Page 8264 > < Controls - Front|Page 8262
Page 6
background image

1. Position the recirculation door actuator (1) to the HVAC air inlet housing. If necessary, rotate the actuator slightly to align the splines on the

actuator output shaft with those in the recirculation-air door linkage.

2. Install the screws (2) that secure the recirculation door actuator (3) to the HVAC air inlet housing (1). Tighten the screws to 2 Nm (17 in. lbs.).

3. Install the air inlet housing to the HVAC housing.

4. Install the HVAC housing.

5. Reconnect the negative battery cable.

6. Initiate the Actuator Calibration function using a scan tool.

Controls - Front|Page 8264 > < Controls - Front|Page 8262