dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Positive Crankcase Ventilation Valve|Removal|Page 4496 > < Positive Crankcase Ventilation Valve|Removal
Page 2
background image

The PCV valve (4) is mounted into the top of the intake manifold (1). This is located to the right / rear of the throttle body (2).

1. The PCV valve is sealed to the intake manifold with 2 O-rings (2).

2. Remove PCV valve by rotating counter-clockwise 90 degrees until locating tabs (3) have been freed. After tabs have cleared, pull valve straight up

from intake manifold.

3. After valve is removed, check condition of 2 valve O-rings (2).

Positive Crankcase Ventilation Valve|Removal|Page 4496 > < Positive Crankcase Ventilation Valve|Removal