dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

All Technical Service Bulletins for Air Duct: > < AC Ducts - Emit Odors
Page 2
background image

-

WEAR SAFETY GLASSES AND GLOVES

-

AVOID BREATHING VAPORS

-

USE WATER TO FLUSH EYES IF NECESSARY

1.

Verify that the A/C condensation drain tube is free from any blockage and drains freely. Correct if necessary.

2.

Protect the interior of the vehicle with a drop cloth.

3.

Start the engine, set the blower on HIGH, air on recirculate, turn the A/C compressor OFF, open all of the instrument panel ducts and vehicle
windows. Run the vehicle for 60 minutes to dry out the evaporator coil.

4.

Switch to outside air. With a shop rag, block about 90% of the outside air inlet to increase air velocity (the outside air inlet is located outside the
vehicle under the cowl on the right side of the dash panel). Open the vehicles doors. On "AS" Body models, remove the resistor block.

**NOTE:

THE THREADS OF THE SCREWS ATTACHING THE RESISTOR BLOCK ARE NOT FULL LENGTH. IT IS NECESSARY TO GENTLY
PRY OUT THE RESISTOR BLOCK WHILE TURNING THE SCREWS COUNTER-CLOCKWISE SO THE THREADS WILL ENGAGE AND
COME OUT.**

5.

Shake the bottle of evaporator cleaner. Connect the bottle and a compressed air supply, with at least 80 PSI of pressure, to the reusable applicator.

6.

Spray the cleaner into the outside air inlet for 20 seconds or until the bottle is completely empty. Spray into the resistor block opening on "AS"
models.

7.

Turn the vehicle OFF and allow to soak for at least 30 minutes.

8.

Wipe off any excess cleaner from around the instrument panel ducts.

9.

Start the engine, set the blower on HIGH, air on recirculate, **turn the A/C compressor OFF, open all of the instrument panel ducts, and open all
of the vehicles windows.** Run the vehicle for 20 minutes to dry the system.

POLICY: Reimbursable within the provisions of the warranty.

TIME ALLOWANCE:
Labor Operation No.

Replace Evaporator

AC & AY 1992 - 1993   

24-65-90-91

2.0 Hrs.

AS 1992 - 1994

24-65-90-91

2.4 Hrs.

Clean Evaporator
AC, AS & AY     24-65-90-90

0.3 Hrs.

FAILURE CODE:

58 - Internal Defect