dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Antilock Brake System Bleeding Procedures|Page 1054 > < Antilock Brake System Bleeding Procedures
Page 2
background image

Fig. 24  Bleeding Brake At Caliper

PRESSURE BLEEDING

The brake lines can be bled using a standard diaphragm type pressure bleeding system. Use only a diaphragm type system to prevent contaminants from
entering the system.

1.

Ensure ignition remains OFF for the entire procedure.

2.

Depressurize the hydraulic accumulator as outlined under "Booster Bleeding."

3.

Disconnect electrical connector from fluid level sensor, then remove reservoir cap.

4.

Install pressure bleeder adapter, then attach bleeding equipment to adapter. Charge pressure bleeder to 20 psi.

5.

Connect a transparent hose to caliper bleed screw, and submerge the other end in a clear container, partially filled with clean brake fluid.

6.

Turn pressure bleeder on, then open caliper bleed screw 1/2-3/4 turn allowing fluid to escape until no more air bubbles are present. If reservoir has
been drained, or hydraulic assembly removed prior to bleeding, pump the brake pedal slowly one or two times with bleed screw open to purge air
from hydraulic assembly.

7.

Repeat step 6 for each caliper in the following order: LR-RR-LF-RF.

8.

After bleeding all calipers, close the pressure bleeder valve and torque to 7.5 lb-ft, then slowly unscrew the bleeder adapter from the hydraulic
assembly reservoir.

9.

Use a syringe or other method to remove excess fluid from reservoir and adjust to the full mark.

10.

Install reservoir cap, connect the fluid level sensor connector, and turn on ignition to allow pump to charge the accumulator.

MANUAL BLEEDING 

1.

Depressurize the hydraulic accumulator as outlined under "Booster Bleeding."

2.

Connect a transparent host to caliper bleed screw, and place the other end of hose in a transparent container partially filled with clean brake fluid.

3.

Slowly pump brake pedal several times with full strokes of the brake pedal. Allow about five seconds between pedal strokes. After two or three
strokes, continue holding pedal under pressure at the bottom of its travel.

4.

Open the bleed screw 1/2-3/4 turn. Keep screw open until fluid no longer comes out from bleeder, then tighten bleeder screw and release brake
pedal.

5.

Repeat this procedure until air bubbles are no longer present in fluid coming from bleeder hose.

6.

Repeat for all wheels in the following order: LR-RR-LF-RF.

Antilock Brake System Bleeding Procedures|Page 1054 > < Antilock Brake System Bleeding Procedures