Oxygen Sensor: Service and Repair

Oxygen Sensor Location

Oxygen Sensor Socket

Warning:  Exhaust manifold becomes very hot during engine operation.
Caution:

The oxygen sensor has a permanently attached wire and connector. This should not be removed or pulled on, as any change in circuit
resistance will affect engine performance and emissions.

Caution:

Excessive force may damage threads in exhaust manifold or pipe.

1.

Disconnect oxygen sensor electrical connector.

2.

Using a suitable tool (tool # C-4907 or equivalent), carefully remove the sensor from exhaust manifold or pipe. The oxygen sensor may be easier
to remove when engine temperature is above 120°F.

3.

Clean threads in exhaust manifold with an 18 mm X 1.5 + 6E tap.

4.

If a new sensor is being used, verify that the threads are coated with anti-seize compound, before installing in manifold or pipe.

4.

If a used sensor is being installed, coat sensor threads with a nickel based anti-seize compound (Loctite 771-64 or equivalent), then install sensor
in manifold or pipe. Do not use graphite or other anti-seize compounds. 

5.

Torque the oxygen sensor to 20 ft-lbs (27 Nm), connect wiring. 