dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Data Link Connector > < Diagram Information and Instructions|Page 2288
Page 4
background image

Distributor Cap Terminal Routing

b.

Rotate the distributor shaft until the rotor points to number one terminal.

c.

Lower the distributor into the opening, engaging the distributor drive with the drive on the cam shaft. With the distributor fully seated the
rotor should be under the number one terminal.

4.

Install the distributor cap, making sure all plug wires are seated securely in the cap towers. Install hold down nut finger tight.

5.

Connect distributor lead wire and negative battery cable lead. Set ignition timing, refer to ADJUSTMENT PROCEDURES for timing
adjustment.

.

Data Link Connector > < Diagram Information and Instructions|Page 2288