Blower Motor Relay: Description and Operation
Front Blower Motor Relay

Circuit Operation

Power for the blower motor is supplied on circuit C71. This circuit is HOT when the contacts in the HVAC blower relay are CLOSED. Power for the
contact side of the relay is supplied on circuit C1.

The C1 circuit is HOT at all times, and protected by a 40 Amp fuse located in cavity 3 of the Power Distribution Center (PDC).

The coil side of the relay is energized when the ignition switch is in the RUN position only. Power for the coil side of the relay is supplied on circuit
A22. This circuit connects from the ignition switch to the relay.

Circuit A2 connects from the fuse 8, a 10 Amp, in the junction block and supplies power for circuit A22.

The A6 circuit supplies power for fuse 10. This circuit is HOT at all times and protected by a 40 Amp fuse located in cavity 6 of the PDC.

Ground for the coil side of the relay is supplied on circuit Z1. This ground terminates at the left cowl panel.