dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Electrical - Locks Inoperative/Liftgate Triggers Alarm|Page 8613 > < Electrical - Locks Inoperative/Liftgate Triggers Alarm
Page 2
background image

3.

If the vehicle operator describes or experiences the Symptom/Condition, use the table to determine the appropriate action.

SPECIAL TOOLS/EQUIPMENT REQUIRED:

NOTE:

An updated J1962 cable has been released. This cable has a red colored connector at the DRBIII(R) connection. Use this cable whenever a flash is
being performed.

REPAIR PROCEDURE:

NOTE:

Whenever a controller is programmed, the software in the DRBIII(R); must be programmed with the latest revision level available.

NOTE:

If this flash process is interrupted/aborted, the flash should be restarted and then follow the directions on the DRBIII(R).

1.

Before beginning the reprogramming procedure, remove any old flash reprogramming files from the DRBIII(R) memory. To clear the memory
from the MAIN MENU:

a.

Simultaneously press the "MORE" and "YES" keys.

b.

A screen will appear requesting a "COLD BOOT".

c.

Follow the on screen instructions by selecting the "F4" key.

d.

When the DRBIII(R) reboots to the MAIN MENU, proceed to Step # 2

2.

Connect the DRBIII(R) to TechCONNECT. Open TechTOOLS and verify that the "DRBIII(R) Status: Connected" message is in the upper right
corner of the TechTOOLS screen.

3.

Enter the "Software part # " recorded during "Diagnosis" in the "Parts Criteria" area and select "Show Updates". TechTOOLS will populate the
available updates.

4.

Select the calibration.

5.

Select the "DRBIII" radio button which is next to the "Download/Update" button.