Leak Detection Pump: Service and Repair
Natural VAC Leak Detection Assy

REMOVAL

1. Disconnect thew negative battery cable.

NVLD Location

2. Raise vehicle and support.
3. Unlock and disconnect the electrical connector.
4. Remove the hoses from the NVLD valve.
5. Remove the 2 fasteners.

NVLD Removal/Installation

6. Remove the valve and bracket from vehicle .