Installation

INSTALLATION

1. Clean any debris off the mating surfaces of the HCU and ABM.

CAUTION:  Do not reuse internal pump connector O-ring or solenoid valve stem seals. They must be replaced to ensure proper sealing.

CAUTION:  When installing new O-rings or solenoid valve stem seals, do not use any type of lubricant.

2. Replace solenoid valve stem seals (Figure 1). These seals can be easily removed and installed by hand. Do not use any type of sharp instrument or

damage to the components may occur.