14.   Inspect and clean manifold. 

Installation

INSTALLATION

1.   Position exhaust manifold on cylinder head and install bolts to center runner (cylinder #3) and initial tighten to 2.8 Nm (25 in. lbs.) (Figure 4) 
2.   Using a new gasket, attach crossover pipe to exhaust manifold and tighten bolts to 41 Nm (30 ft. lbs.) (Figure 3).

NOTE: Inspect crossover pipe fasteners for damage from heat and corrosion. The cross-over bolts are made of a special stainless steel
alloy. If replacement is required, OEM bolts are highly recommended.
 

3.   Install the remaining manifold attaching bolts. Tighten all bolts to 23 Nm (200 in. lbs.).
4.   Position the power steering pump support strut and install upper bolt (Figure 1).
5.   Install heat shield and attaching screws (Figure 4).
6.   Install and connect upstream oxygen sensor (Figure 4).
7.   Raise the vehicle.
8.   Attach catalytic converter pipe to exhaust manifold using new gasket and tighten bolts to 37 Nm (27 ft. lbs.) (Figure 2).
9.   Connect downstream oxygen sensor connector.

10.   Tighten the power steering pump support strut lower bolt (Figure 1).
11.   Install the belt splash shield and lower the vehicle.
12.   Install the wiper module. 
13.   Connect battery negative cable.

Figure 1 P/S PUMP STRUT

Procedures|Page 2988 > < Procedures|Page 2986