dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Removal - Front
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair
Installation - Front

INSTALLATION

NOTE:  Use only the specified O-ring as it is made of special material for R-134a. Use only refrigerant oil of the type required for the A/C compressor.

1. Lubricate a new rubber O-ring seal with clean refrigerant oil and install it on the liquid line fitting.

2. Install the A/C pressure transducer onto the liquid line. Tighten the A/C pressure transducer securely.

3. Connect the wire harness connector to the A/C pressure transducer.

4. Reconnect the negative battery cable.