dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Refrigerant System Recovery|Page 8180 > < Refrigerant System Recovery|Page 8178
Page 1
background image

Refrigerant: Tools and Equipment

REFRIGERANT SYSTEM SERVICE EQUIPMENT

WARNING: Refer to the applicable warnings and cautions for this system before performing the following operation See: Service
Precautions/Warning and See: Service Precautions/Caution. Failure to follow the warnings and cautions may result in serious or fatal injury

WARNING: Eye protection must be worn when servicing an A/C refrigerant system. Turn all valves off (rotate clockwise) on the equipment
being used before connecting or disconnecting service equipment from the refrigerant system. Failure to observe these warnings may result in
serious or fatal injury.

When servicing the A/C system, a R-134a refrigerant recovery/recycling/charging station that meets SAE standard J2210 must be used (1). Contact an
automotive service equipment supplier for refrigerant recovery/recycling/charging equipment

A manifold gauge set (1) may be needed with some recovery/recycling/charging equipment. The manifold gauge set should have manual shut-off valves
(2 and 6), or automatic back-flow valves located at the service port connector end of the manifold gauge set hoses (4 and 5). This will prevent refrigerant
from being released into the atmosphere.

MANIFOLD GAUGE SET CONNECTIONS

CAUTION: Do not use an R-12 manifold gauge set on an R-134a system. The refrigerants are not compatible and system damage will result.

RECOVERY/RECYCLING/EVACUATION/CHARGING HOSE  The center manifold hose (Yellow, or White, with Black stripe) (3) is used to
recover, evacuate, and charge the refrigerant system. When the low or high pressure valves on the manifold gauge set are opened, the refrigerant in the

Refrigerant System Recovery|Page 8180 > < Refrigerant System Recovery|Page 8178