dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Ambient Temperature Sensor Circuit Test|Page 6836 > < Ambient Temperature Sensor Circuit Test
Page 1
background image

Ambient Temperature Sensor / Switch HVAC: Testing and Inspection
Ambient Temperature Sensor Test

1. Turn the ignition switch to the OFF position. Disconnect and isolate the battery negative cable. Disconnect the ambient temperature sensor wire

harness connector.

2. Measure the resistance of the ambient temperature sensor. At -40 °C (-40 °F), the sensor resistance is 336 kilo ohms. At 55 °C (140 °F), the

sensor resistance is 2.488 kilo ohms. The sensor resistance should read between these two values. If OK, refer to Diagnosis and Testing - Ambient
Temperature Sensor Circuit. If not OK, replace the faulty ambient temperature sensor.

Ambient Temperature Sensor Circuit Test|Page 6836 > < Ambient Temperature Sensor Circuit Test