dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Troubleshooting|Page 6764 > < Troubleshooting|Page 6762
Page 2
background image

Fig 3 Alternator Output Wire Resistance Test

3. Connect a 0-150 amp D.C. ammeter in series between alternator "B+" terminal and disconnected "B+" lead wire.
4. Connect positive lead wire of a suitable voltmeter to disconnected "B+" lead wire, then connect negative lead to battery positive post.
5. Remove air hose between Engine Controller and air cleaner.

Fig. 4 Alternator Connections (Plug Type)

Troubleshooting|Page 6764 > < Troubleshooting|Page 6762