dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

All Other Service Bulletins for Air Bag:|242193 > < A/C Evaporator - High Pitched Whistle Noise
Page 2
background image

7.

Remove the two screws attaching the expansion valve to the evaporator sealing plate.

8.

Carefully remove the expansion valve and the two aluminum gaskets.

9.

Place a new gasket (P/N 4677045) on the evaporator sealing plate.

10.

Carefully hold the new expansion valve (P/N 4677334) to the evaporator sealing plate, DO NOT SCRATCH THE SEALING SURFACES. Install
the two attaching screws and torque to 70 - 130 in.lbs. (8-14 N-m).

11.

Place a new gasket (P/N 3846834) on the refrigerant line sealing plate.

12.

Carefully hold the refrigerant line sealing plate to the expansion valve, DO NOT SCRATCH THE SEALING SURFACES. Install the attaching
bolt and torque to 170 - 230 in.lbs. (20 - 26 N-m.).

13.

Connect the wire connectors to the low pressure cut-off switch and the ECCS.

14.

Evacuate and recharge the A/C system.

POLICY: Reimbursable within the provisions of the warranty.

TIME ALLOWANCE:
Labor Operation No:

24-35-20-90

0.8 Hrs.

FAILURE CODE: P8 - New Part