Brake Fluid Pump: Description and Operation
Integrated Control Unit (ICU)
GENERAL INFORMATION
The Hydraulic Control Unit (HCU) contains 2 pump assemblies, one for the primary and one for the secondary hydraulic circuit of the brake
system. Both pumps are driven by a common electric motor which is part of the HCU. The pumps draw brake fluid from the fluid accumulators to
supply build pressure to the brakes during an ABS stop. The pump motor runs during an ABS stop and is controlled by the Controller Antilock
Brake (CAB). The pump/motor assembly is not a serviceable item. If the pump/motor requires replacement, the complete HCU (minus the CAB)
must be replaced.
NOTE: The pump is an integrated component of the HCU.