dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

A/C - Temperature Difference Between Panel Vents|Page 7283 > < A/C - Evaporator Hissing Sound|Page 7278
Page 1
background image

Evaporator Core: Customer Interest
A/C - Temperature Difference Between Panel Vents

NUMBER: 24-007-02

GROUP: Heating & A/C

DATE: Aug. 5, 2002

SUBJECT:
A/C Temperature Differential (Stratification) Between Left and Right Front Panel Outlets

OVERVIEW:
This bulletin involves diagnosing A/C temperature difference (stratification) between the left and right front panel outlets.

MODELS:
2001 - 2002 (RS) Town & Country/Caravan/Voyager
2001 - 2002 (RG) Chrysler Voyager (International Markets)

NOTE:

THIS BULLETIN APPLIES TO RS/RG VEHICLES EQUIPPED WITH DUAL ZONE MANUAL (HAD), 3 ZONE MANUAL (HAG), OR ATC
(HAH) CLIMATE CONTROL SYSTEMS

SYMPTOM/CONDITION:

More than 12°F warmer outlet air temperature on the left front panel outlet as compared to the right front panel outlet when the HVAC controls are set to
max cold.

DIAGNOSIS:

Set the A/C controls so that the compressor is engaged, the air within the vehicle is being recirculated, the output air is being directed through the panel
outlets, the temperature control is in the full cool position, and the front and rear (if equipped with rear A/C) blower motor(s) are operating at their
highest speed. Use a temperature probe to measure the front left and right panel outlet temperatures. If the difference between the two panel outlets is
greater than 12°F, perform the diagnostic procedure below.

EQUIPMENT REQUIRED

DIAGNOSTIC PROCEDURE:

1.

Connect DRBIII(R) and check for A/C related Diagnostic Test Codes (DTC). If DTCs are present, repair them using appropriate body diagnostic
manual (Heating & A/C section for manual systems and Automatic Temperature Control section for ATC systems) and clear any fault codes
related to A/C.

2.

Use DRBIII(R) to perform a Heater - A/C Control Calibration as outlined in the appropriate Service Manual (section 24, Controls - Front).

a.

If calibration passes, recheck the A/C panel outlet temperature stratification.

b.

If the calibration fails: Use the DRBIII(R) for further diagnosis of the DTC's in the appropriate body diagnostic manual (Heating & A/C
Diagnostic section) and correct the problem. After calibration is successful, check the A/C panel outlet stratification.

3.

Use the DRBIII(R) to perform an A/C Cool Down Test as outlined in the appropriate service manual (section 24, Diagnosis and testing).

a.

If the cool down test fails, proceed to A/C Performance Test and verify performance against the temperature and pressure chart in the
service manual (Section 24, Diagnosis and Testing). Add refrigerant if necessary and check the A/C panel outlet stratification.

4.

Perform diagnosis and testing of expansion valve as described in the appropriate service manual (section 24, Plumbing - Front, Expansion Valve).

a.

If the expansion valve fails the test - replace the expansion valve as described in the service manual and proceed to step 5 of this procedure.

b.

If the expansion valve passes, review the warranty history for previous compressor failures. If a compressor has previously failed and the
expansion valve and/or receiver/drier was not replaced at that time, replace both the expansion valve and receiver/drier.

A/C - Temperature Difference Between Panel Vents|Page 7283 > < A/C - Evaporator Hissing Sound|Page 7278