Expansion Valve: Service and Repair
Front

REMOVAL

WARNING:  REFER TO THE APPLICABLE WARNINGS AND CAUTIONS FOR THIS SYSTEM BEFORE PERFORMING THE
FOLLOWING OPERATION.

1. Recover the refrigerant from the refrigerant system.
2. Disconnect and isolate the battery negative cable.
3. Remove the air cleaner housing from the right side of the engine compartment.
4. Disconnect the drain tube from the wiper module drain on the right side of the engine compartment.

Fig.14 Expansion Valve

5. Disconnect the headlamp and dash wire harness connector for the A/C pressure transducer from the transducer on the front liquid line rear section.
6. Remove the screw that secures the front liquid line rear section fitting to the top of the filter-drier.
7. Disconnect the liquid line fitting from the filter-drier outlet port.
8. Remove the seal from the liquid line fitting and discard.
9. Install plugs in, or tape over the opened liquid line fitting and the filter-drier outlet port.

10. Remove the nut that secures the suction line and liquid line fittings to the stud on the expansion valve.
11. Disconnect the suction line and liquid line fittings from the expansion valve and move the lines out of the way
12. Remove the seals from the suction line and liquid line fittings and discard.
13. Install plugs in, or tape over the opened suction line and liquid line fittings and both expansion valve ports.
14. Remove the two screws that secure the expansion valve to the evaporator tube tapping plate.
15. Disconnect the HVAC wire harness connector for the evaporator temperature sensor from the sensor on the top of the expansion valve.
16. Remove the expansion valve from the evaporator inlet and outlet tube fittings.
17. Remove the seals from the evaporator inlet and outlet tube fittings and discard.
18. Install plugs in, or tape over the opened evaporator inlet and outlet tube fittings and both expansion valve ports.

INSTALLATION

1. Remove the tape or plugs from the evaporator inlet and outlet tube fittings and both ports on the back of the expansion valve.
2. Lubricate new rubber O-ring seals with clean refrigerant oil and install them on the evaporator inlet and outlet tube fittings.
3. Position the expansion valve onto the evaporator inlet and outlet tube fittings.
4. Install and tighten the two screws that secure the expansion valve to the evaporator tube tapping plate plate. Tighten the screws to 11 Nm (97 in.

lbs.).

5. Reconnect the HVAC wire harness connector for the evaporator temperature sensor to the sensor connector receptacle on the top of the expansion

valve.

6. Remove the tape or plugs from the front liquid line rear section and suction line fittings for the expansion valve and both ports on the front of the

expansion valve.

7. Lubricate new rubber O-ring seals with clean refrigerant oil and install them on the front liquid line rear section and suction line fittings for the 

expansion valve.

8. Reconnect the liquid line and suction line fittings to the expansion valve.