dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Downstream 2/1 Oxygen Sensor Replacement|Page 2475 > < Downstream 2/1 Oxygen Sensor Replacement
Page 2
background image

Fig. 19 O2 Sensor Downstream 1/2

4. Use a socket such as the Snap-On(R) YA8875 or equivalent to remove the sensor.
5. When the sensor is removed, the threads must be cleaned with an 18 mm X 1.5 + 6E tap. If using the original sensor, coat the threads with Loctite 

771-64 anti-seize compound or equivalent.

INSTALLATION

The O2S are located on the side of the catalytic converter.

Threads of new oxygen sensors are factory coated with anti-seize compound to aid in removal. DO NOT add any additional anti-seize compound to
the threads of a new oxygen sensor.
1. Install sensor and tighten to 27 Nm (20 ft. lbs.).
2. Connect the electrical connector.
3. Lower vehicle.
4. Install the negative battery cable.

Downstream 2/1 Oxygen Sensor Replacement|Page 2475 > < Downstream 2/1 Oxygen Sensor Replacement