dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC > < Component Locations|Page 7715
Page 1
background image

Evaporator Temperature Sensor / Switch: Service and Repair

REMOVAL

1. Disconnect battery.
2. Remove right under panel silencer.
3. Disconnect wiring connector for evaporator probe.

Evaporator Probe

4. At center of heater housing, locate evaporator probe access plate. Using a flat blade pry tool, pull back on the locking tab. Twist the access plate

counter clockwise one-quarter turn and remove plate.

5. Pull probe out of evaporator core. This plate must be pushed inside the A/C unit and orientated in such a way that the plate can be removed.

INSTALLATION

Evaporator Probe

1. Install new probe into the evaporator. The new probe must not go into the same hole (in the evaporator core) that the old probe was removed. The

evaporator is manufactured with three holes for probe insertion. Insert the probe in the uppermost hole.

2. Install evaporator probe access panel.
3. Connect probe wiring harness.
4. Reconnect battery.

Refrigerant Pressure Sensor / Switch, HVAC > < Component Locations|Page 7715