dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Cooling Fan - Noise/Poor Idle Quality|Page 104 > < Diagram Information and Instructions|Page 94
Page 1
background image

Radiator Cooling Fan Control Module: Customer Interest
Cooling Fan - Noise/Poor Idle Quality

NO: 18-20-96

GROUP: Vehicle Performance

DATE: Aug. 2, 1996

SUBJECT:
Cooling Fan Noise/Idle Quality

THIS BULLETIN SUPERSEDES TECHNICAL SERVICE BULLETIN 07-06-94 DATED SEPT. 2, 1994 WHICH SHOULD BE REMOVED FROM
YOUR FILES AND NOTED IN THE 1994 TECHNICAL SERVICE BULLETIN MANUAL (PUBLICATION NO.81-699-95054). ADDITIONAL
MODELS, REVISED PARTS AND PROCEDURES HAVE BEEN ADDED. ALL CHANGES ARE MARKED WITH **ASTERISKS**.

MODELS:

**1993 - 1996** (LH) Concorde/Intrepid/Vision/LHS/New Yorker

**NOTE:

THIS BULLETIN APPLIES TO VEHICLES BUILT BEFORE DEC. 31, 1995 (MDH-12-31-XX) EQUIPPED WITH A 3.5L ENGINE**.

SYMPTOM/CONDITION:

An audible "beat/boom" sound inside the passenger compartment when the vehicle is idling in drive, A/C on and the fan module is operating on high
speed. This may also be described as poor idle quality.

DIAGNOSIS:

Many factors can contribute to this noise and vibration conditions. Use the following procedure to identify a noisy fan module.

1.

Run vehicle with A/C off and cardboard between the radiator and condenser.

2.

Using the DRB III, monitor coolant temperature and coolant fan mode.

3.

Allow coolant temperature to rise to approximately 230 degrees F wherein the high speed fan will come on (to accelerate coolant temperature rise,
run the engine at 2000 - 2500 RPM).

4.

Remove cardboard.

5.

Compare noise/vibration inside the closed vehicle, while idling in drive, under the following conditions:

^

High speed fan on.

^

High and low speed fans off (engine only), which occurs when coolant temperature drops below 200 degrees F.

6.

If noise/vibration occurs only when the fans are on low or off, the problem may be caused by the engine. Perform the appropriate engine
diagnostics. If the noise increases when the fans are on high speed, perform the Repair Procedure.

**NOTE:

TO ADDRESS IDLE QUALITY CONDITIONS, REFER TO THE TSB'S LISTED BELOW AND PERFORM THE REPAIRS AS
NECESSARY.

1993-1994 M.Y.,

TECHNICAL SERVICE BULLETIN 18-29-94 DATED JAN. 13, 1995
INSTALL REVISED SPARK PLUGS AND UPDATE PCM

1995 M.Y.,

TECHNICAL SERVICE BULLETIN 18-15-95 DATED MAY 5, 1995
INSTALL REVISED SPARK PLUGS AND REPROGRAM THE PCM

1996 M.Y.,

NOT INVOLVED**

PARTS REQUIRED:

1

**4596212** Fan Module

Cooling Fan - Noise/Poor Idle Quality|Page 104 > < Diagram Information and Instructions|Page 94