Journey FWD V6-3.5L (2009)
3. Install the screws (1) that secure the recirculation door actuator (2) to the air inlet housing (3). Tighten the screws to 2 Nm (17 in. lbs.).
4. Connect the instrument panel wire harness connector (4) to the recirculation door actuator.
5. Install the glove box binSee: Body and Frame/Interior Moulding / Trim/Glove Compartment/Service and Repair/Instrument Panel Glove Box -
Installation.
6. Reconnect the negative battery cable.
7. Initiate the Actuator Calibration function using a scan tool See: Testing and Inspection/Component Tests and General Diagnostics/HVAC System
Test.