dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 5427 > < Diagram Information and Instructions|Page 5425
Page 2
background image

 

1. Remove the fuse (1) for the circuit being checked or, disconnect the battery. 
2. Connect one lead of the ohmmeter to one side of the circuit being tested 
3. Connect the other lead to the other end of the circuit being tested. Low or no resistance means good continuity.

Testing For A Short To Ground

TESTING FOR A SHORT TO GROUND

 

1. Remove the fuse and disconnect all items involved with the fuse. 
2. Connect a test light or a voltmeter across the terminals of the fuse. 
3. Starting at the fuse block, wiggle the wiring harness about six to eight inches apart and watch the voltmeter/test lamp. 
4. If the voltmeter registers voltage or the test lamp glows, there is a short to ground in that general area of the wiring harness.

Testing For A Short To Ground On Fuses Powering Several Loads

TESTING FOR A SHORT TO GROUND ON FUSES POWERING SEVERAL LOADS

 

1. Refer to the wiring diagrams and disconnect or isolate all items on the suspected fused circuits. 
2. Replace the blown fuse. 
3. Supply power to the fuse by turning ON the ignition switch or re-connecting the battery. 
4. Start connecting or energizing the items in the fuse circuit one at a time. When the fuse blows the circuit with the short to ground has been isolated.

Testing For A Voltage Drop

TESTING FOR A VOLTAGE DROP

 

 

1. Connect the positive lead of the voltmeter to the side of the circuit closest to the battery. 
2. Connect the other lead of the voltmeter to the other side of the switch, component or circuit. 
3. Operate the item. 
4. The voltmeter will show the difference in voltage between the two points.

Troubleshooting Wiring Problems

WIRING HARNESS

 

TROUBLESHOOTING TOOLS

 
When diagnosing a problem in an electrical circuit there are several common tools necessary. These tools are listed and explained below.
 

-

Jumper Wire - This is a test wire used to connect two points of a circuit. It can be used to bypass an open in a circuit.

 

WARNING: Never use a jumper wire across a load, such as a motor, connected between a battery feed and ground.