dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Evaporative Emissions System > < Catalytic Converter|Removal
Page 1
background image

Catalytic Converter: Service and Repair
Installation

LEFT HAND CATALYTIC CONVERTER

1.   Install catalytic converter (3) onto exhaust manifold ball flange. Only finger tighten nuts at this time.
2.   Install muffler and resonator assembly.
3.   Install bolts and cross brace. Tighten bolts to 55 Nm (40 ft. lbs.).
4.   Tighten manifold ball flange nut to 12 Nm (106 in. lbs.).
5.   Check clearance between exhaust module and fuel tank. Clearance is 14mm (.55 in.) for V8 engine and 16mm (.62 in.) for V6 engine.
6.   Check clearance at rear tunnel reinforcement. Clearance is 15 - 20mm (.59 -.78 in.).
7.   Adjust clearance as necessary.
8.   Tighten ball flange nuts to 34 Nm (25 ft. lbs.).
9.   Lower vehicle.

10.   Connect negative battery cable.
11.   Start the engine and inspect for exhaust leaks. Repair exhaust leaks as necessary.