dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Recall - Cat Converter Replacement/PCM Update|Page 2600 > < Recall - Cat Converter Replacement/PCM Update|Page 2598
Page 4
background image

1.

Raise the vehicle on a suitable hoist.

2.

Disconnect the electrical harness connector from the left downstream oxygen sensor.

3.

Remove the right downstream oxygen sensor connector from the transmission support crossmember.

4.

Disconnect the electrical harness connector from the right downstream oxygen sensor.

5.

Remove both the left and right downstream oxygen sensors from the exhaust catalyst assemblies using special tool C-4907.

6.

Remove the brace (if so equipped) at the rear of front exhaust catalyst assemblies (Figure 1).

7.

Loosen the two clamps holding the right and left front exhaust catalyst assemblies to the "Y" collector pipe (Figure 2).

8.

Remove the front and rear resonator isolator hanger bolts.

9.

Separate the remaining rubber isolator hangers from the exhaust system (Figure 1).

10.

Support the muffler and tailpipe assembly with a suitable jack.

11.

Separate the exhaust system at the "Y" connector from the right and left exhaust catalyst assemblies (Figure 2).

Recall - Cat Converter Replacement/PCM Update|Page 2600 > < Recall - Cat Converter Replacement/PCM Update|Page 2598