dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

NAG1 Automatic Transmission|Page 4429 > < NAG1 Automatic Transmission|Page 4427
Page 13
background image

The torque converter lockup clutch PWM solenoid valve (1) is located in the shell of the electric valve control unit and pressed against the shift plate
by a spring.
The PWM solenoid valve (1) for the torque converter lockup controls the pressure for the torque converter lockup clutch.
The torque converter lockup PWM solenoid valve (1) is sealed off to the valve body of the shift plate (4) by an O-ring (5) and a seal (arrow). The
contact springs (2) at the solenoid valve engage in a slot in the conductor tracks (3). The force of the contact springs (2) ensures secure contacts.

SHIFT PRESSURE CONTROL SOLENOID VALVE

The shift pressure control solenoid valve (1) is located in the shell of the electric valve control unit and pressed against the shift plate by a spring.
Its purpose is to control the shift pressure depending on the continuously changing operating conditions, such as load and gear change.
The shift pressure regulating solenoid valve (1) has an interference fit and is sealed off to the valve body of the shift plate (4) by a seal (arrow). The
contact springs (2) at the solenoid valve engage in a slot in the conductor tracks (3). The force of the contact springs (2) ensures secure contacts.

OPERATION

When an electrical current is applied to the solenoid coil, a magnetic field is created which produces an attraction to the plunger, causing the plunger
to move and work against the spring pressure and the load applied by the fluid the valve is controlling. The plunger is normally directly attached to the
valve which it is to operate. When the current is removed from the coil, the attraction is removed and the plunger will return to its original position due
to spring pressure.

The plunger is made of a conductive material and accomplishes this movement by providing a path for the magnetic field to flow. By keeping the air gap
between the plunger and the coil to the minimum necessary to allow free movement of the plunger, the magnetic field is maximized.

UPSHIFT/DOWNSHIFT SOLENOID VALVES

NAG1 Automatic Transmission|Page 4429 > < NAG1 Automatic Transmission|Page 4427