dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

NAG1 Automatic Transmission|Page 5562 > < NAG1 Automatic Transmission|Page 5560
Page 12
background image

UPSHIFT/DOWNSHIFT SOLENOID VALVES

The solenoid valves (1) for upshifts and downshifts are located in the shell of the electric control unit and pressed against the shift plate with a spring.
The solenoid valves (1) initiate the upshift and downshift procedures in the shift plate.
The solenoid valves (1) are sealed off from the valve housing of the shift plate (5) by two O-rings (4, 6). The contact springs (8) at the solenoid valve
engage in a slot in the conductor tracks (7). The force of the contact spring (8) ensures safe contacts.

MODULATING PRESSURE CONTROL SOLENOID VALVE

The modulating pressure control solenoid valve (1) is located in the shell of the electric valve control unit and pressed against the shift plate by a
spring.
Its purpose is control the modulating pressure depending on the continuously changing operating conditions, such as load and gear change.
The modulating pressure regulating solenoid valve (1) has an interference fit and is sealed off to the valve body of the shift plate (4) by a seal (arrow).
The contact springs (2) at the solenoid valve engage in a slot in the conductor tracks (3). The force of the contact springs (2) ensures secure contacts.

TORQUE CONVERTER LOCKUP CLUTCH PWM SOLENOID VALVE

NAG1 Automatic Transmission|Page 5562 > < NAG1 Automatic Transmission|Page 5560