dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

A/T Controls - MIL ON/DTC P0741 Set|Page 673 > < A/T Controls - MIL ON/DTC P0741 Set
Page 2
background image

SPECIAL TOOLS / EQUIPMENT REQUIRED:

REPAIR PROCEDURE - USING THE INTERNET TO RETRIEVE THE FLASH FILE:

NOTE:

When performing this Repair Procedure, the software release level in the StarSCAN(R); must be programmed with 8.01 software or higher. The
software release level is visible in the blue header at the top of the StarSCAN(R) screen.

NOTE:

The StarSCAN(R) diagnostic scan tool fully supports Internet connectivity. However, to take advantage of this feature you must first configure the
StarSCAN(R) for your dealership's network. Make sure the StarSCAN(R) is configured to the dealership's network before proceeding. For
instruction on setting up your StarSCAN(R) for the dealer's network refer to either:

"DealerCONNECT > Service > StarSCAN and StarMOBILE tools > Online Documentation", or refer to the StarSCAN(R) Quick Start Networking
Guide. The StarSCAN(R) Quick Start Networking Guide is also available on the website under the "Download Center".

NOTE:

If this flash process is interrupted/aborted, the flash should be restarted.

1.

Open the hood and install a battery charger. Using a voltmeter, verify that the charging rate provides 13.2 - 13.5 volts. Set the battery charger to
continuous charge. Do not allow the charger to time out during the flash process. Remove the charger from the battery when the flash process is
complete.

NOTE:

Do not allow the charging voltage to climb above 13.5 volts during the flash process.

2.

Connect the CH9410 StarSCAN(R) ethernet cable to the StarSCAN(R) and the dealer's network drop.

3.

Connect the CH9404 StarSCAN(R) vehicle cable to the StarSCAN(R) and the vehicle.

4.

Power ON the StarSCAN(R).

5.

Select "ECU View"

6.

Touch the screen to highlight the appropriate ECU in the list of modules.

7.

Select "More Options

8.

Select "ECU Flash"

9.

Record the part number at the top of the "Flash TCM" screen for later reference.

10.

Select "Browse for New File". Follow the on screen instructions.

11.

Highlight the calibration then select "Download to Scantool".

12.

Select "Close after the download is complete, then select "Back".

13.

Highlight the listed calibration.

14.

Select "Update Controller". Follow on screen instructions.

A/T Controls - MIL ON/DTC P0741 Set|Page 673 > < A/T Controls - MIL ON/DTC P0741 Set