dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Hose/Line HVAC|Service and Repair > < Plumbing|Page 1213
Page 1
background image

Hose/Line HVAC: Testing and Inspection

WARNING:

-

R-134A SERVICE EQUIPMENT OR VEHICLE A/C SYSTEM SHOULD NOT BE PRESSURE TESTED OR LEAK TESTED WITH
COMPRESSED AIR. MIXTURE OF AIR AND R-134A CAN BE COMBUSTIBLE AT ELEVATED PRESSURES. THESE MIXTURES
ARE POTENTIALLY DANGEROUS AND MAY RESULT IN FIRE OR EXPLOSION CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR DEATH.

-

AVOID BREATHING A/C REFRIGERANT AND LUBRICANT VAPOR OR MIST. EXPOSURE MAY IRRITATE EYES, NOSE AND
THROAT. USE ONLY APPROVED SERVICE EQUIPMENT MEETING SAE REQUIREMENTS TO DISCHARGE R-134A SYSTEM.
IF ACCIDENTAL SYSTEM DISCHARGE OCCURS, VENTILATE WORK AREA BEFORE RESUMING SERVICE
.

If the A/C system is not cooling properly, determine if the refrigerant system is fully charged with R-134a. This is accomplished by performing a system
Charge Level-Check or Fill. If while performing this test A/C liquid line pressure is less than 345 kPa (50 psi) proceed to System Empty procedure. If
liquid line pressure is greater than 345 kPa (50 psi) proceed to System Low procedure. If the refrigerant system is empty or low in refrigerant charge, a
leak at any line fitting or component seal is likely. A review of the fittings, lines and components for oily residue is an indication of the leak location. To
detect a leak in the refrigerant system, perform one of the following procedures as indicated by the symptoms.

SYSTEM EMPTY

1. Evacuate the refrigerant system to the lowest degree of vacuum possible (approximately 28 in Hg.). Determine if the system holds a vacuum for 

15 minutes. If vacuum is held, a leak is probably not present. If system will not maintain vacuum level, proceed to Step 2.

2. Prepare a 0.284 Kg. (10 oz.) refrigerant charge to be injected into the refrigerant system.
3. Connect and dispense 0.284 Kg. (10 oz.) of refrigerant into the evacuated refrigerant system.
4. Proceed to Step 2 of System Low procedure.

SYSTEM LOW

1. Determine if there is any R-134a refrigerant in the system.
2. Position the vehicle in a wind free work area. This will aid in detecting small leaks.
3. Bring the refrigerant system up to operating temperature and pressure. This is done by allowing the engine to run for five minutes with the A/C

system set to the following:
-

Transmission in Park or Neutral with parking brake set

-

Engine idling

-

Mode control set to the outside air position

-

Blower control set to the high speed position

-

A/C set to the ON position

-

All windows open

CAUTION:  A leak detector only designed for R-12 refrigerant will not detect leaks in a R-134a refrigerant system.

4. Shut the vehicle Off and wait 2-7 minutes. Then use an electronic leak detector that is designed to detect R-134a refrigerant and search for leaks.

Fittings, lines or components that appear to be oily usually indicate a refrigerant leak. To inspect the A/C evaporator for leaks, insert the leak
detector probe into the drain tube opening or an air outlet. A dye for R-134a is available to aid in leak detection. Use only DaimlerChrysler
approved refrigerant dye.

Hose/Line HVAC|Service and Repair > < Plumbing|Page 1213