dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Diagrams|Page 6248
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

TRANSDUCER-A/C PRESSURE

REMOVAL

NOTE:

-

It is not necessary to discharge the refrigerant system to replace the A/C pressure transducer.

-

LHD model shown. RHD model similar.

1. Disconnect and isolate the negative battery cable.
2. Disconnect the wire harness connector (1) from the A/C pressure transducer (2).
3. Remove the A/C pressure transducer from the A/C liquid line (3) and remove and discard the O-ring seal.

INSTALLATION

NOTE:

-

Use only the specified O-ring as it is made of special material for R-134a. Use only refrigerant oil of the type required for the A/C compressor.

-

LHD model shown. RHD model similar.

1. Lubricate a new rubber O-ring seal with clean refrigerant oil and install it onto the liquid line fitting.
2. Install the A/C pressure transducer (2) onto the A/C liquid line (3). Tighten the A/C pressure transducer securely.
3. Connect the wire harness connector (1) to the A/C pressure transducer.
4. Reconnect the negative battery cable.

Solar Sensor, HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Diagrams|Page 6248