dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Overdrive Solenoid, A/T|Description and Operation|Page 3214 > < Overdrive Solenoid, A/T|Description and Operation
Page 2
background image

The electric valve control unit (7) consists of a plastic shell which houses the RPM sensors (1,12), regulating solenoid valves (3, 4), solenoid valves
(5, 6, 10), the TCC solenoid valve (11), the park/neutral contact (9), and the transmission oil temperature sensor (8). Conductor tracks integrated into
the shell connect the electric components to a plug connection (2). This 13-pin plug connection (2) establishes the connection to the vehicle-side cable
harness and to the transmission control module (TCM) With the exception of the solenoid valves, all other electric components are fixed to the
conductor tracks.

HYDRAULIC CONTROL UNIT
Working Pressure (Line Pressure or Operating Pressure) (p-A)

The working pressure provides the pressure supply to the hydraulic control and the transmission shift elements. It is the highest hydraulic pressure in
the entire hydraulic system. The working pressure is regulated at the working pressure regulating valve in relation to the load and gear. All other
pressures required for the transmission control are derived from the working pressure.

Lubrication Pressure (p-Sm)

At the working pressure regulating valve surplus oil is diverted to the lubrication pressure regulating valve, from where it is used in regulated amounts
to lubricate and cool the mechanical transmission components and the torque converter. Furthermore, the lubrication pressure (p-Sm) is also used to
limit the pressure in the torque converter.

Shift Pressure (p-S)

The shift pressure is determined by the shift pressure regulating solenoid valve and the shift pressure regulating valve. The shift pressure:
^

Regulates the pressure in the activating shift element during the shift phase.

^

Determines together with the modulating pressure the pressure reduction at the deactivating shift element as regulated by the overlap regulating
valve.

^

Initializes 2nd gear in limp-home mode.

Modulating Pressure (p-Mod)

The modulating pressure influences the size of the working pressure and determines together with the shift pressure the pressure regulated at the
overlap regulating valve. The modulating pressure is regulated at the modulating pressure regulating solenoid valve, which is under regulating valve
pressure. The modulating pressure is variable and relative to the engine load.

Regulating Valve/Control Valve Pressure (p-RV)

The regulating valve pressure is regulated at the regulating valve pressure regulating valve in relation to the working pressure (p-A) up to a maximum
pressure of 8 bar (116 psi). It supplies the modulating pressure regulating solenoid valve, the shift pressure regulating solenoid valve and the shift
valve pressure regulating valve.

Shift Valve Pressure (p-SV)

The shift valve pressure (p-SV) is derived from the regulating valve pressure (p-RV), is regulated at the shift valve pressure regulating valve and is
then present at the:
^

1-2 and 4-5 shift solenoid valve.

^

3-4 shift solenoid valve.

^

2-3 shift solenoid valve.

^

Torque converter lockup solenoid valve.

^

3-4 and 2-3 shift pressure shift valve. 

The shift valve pressure (p-SV) controls the command valves via the upshift/downshift solenoid valves.

Overlap Pressure (p-U)

Overdrive Solenoid, A/T|Description and Operation|Page 3214 > < Overdrive Solenoid, A/T|Description and Operation