dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Pressure Regulating Solenoid, A/T|Description and Operation|Page 3242 > < Pressure Regulating Solenoid, A/T|Description and Operation|Page 3240
Page 6
background image

The lubrication pressure regulating valve (1) is located in the valve housing of the electrohydraulic control module. The valve controls the fluid to
lubricate and cool the mechanical part of the transmission, and limits the pressure in the torque converter.

Shift Pressure Regulating Valve

The shift pressure regulating valve (1) is located in the valve housing of the shift plate. It regulates the shift pressure (p-S).

Regulating Valve Pressure Regulating Valve

The regulating valve pressure regulating valve (1) is located in the valve housing of the electrohydraulic control module. It regulates the regulating
valve/control valve pressure (p-RV).

Shift Valve Pressure Regulating Valve

Pressure Regulating Solenoid, A/T|Description and Operation|Page 3242 > < Pressure Regulating Solenoid, A/T|Description and Operation|Page 3240