dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Solenoid-Pressure Switch Assembly|Page 4185 > < Solenoid-Pressure Switch Assembly|Page 4183
Page 9
background image

During the shift phase the pressure in the deactivating shift actuator is regulated in relation to the engine load (modulating pressure, p-Mod) and the
pressure in the activating actuator. The regulated pressure is inversely proportional to the transfer capacity of the activating shift actuator (regulated
overlap).

Command Valve

Command Valve

When the end face is unpressurized (stationary phase), the working pressure (p-A) is directed to the actuated shift element. If the end face of the
command valve is subjected to the shift valve pressure (p-SV) (shift phase), then the shift pressure (p-S) is switched to the activating element and the
overlap pressure (p-U) is switched to the deactivating element.

Shift Valve Holding Pressure

Shift Valve Holding Pressure

The holding pressure shift valve (1) is actuated by the pressures present at the end face in the actuators and a spring. It assigns the working pressure
(p-A) to the actuator with the higher pressure (taking into account the spring force and the effective surface area). The other element of the shift group
is then unpressurized. The valve switches over only during the shift phase and only at a certain pressure ratio between the overlap pressure (p-U) and
the shift pressure (p-S).

Shift Pressure Shift Valve

Solenoid-Pressure Switch Assembly|Page 4185 > < Solenoid-Pressure Switch Assembly|Page 4183