dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Relays and Modules - Ignition System > < Electrical Specifications|Page 1169
Page 2
background image

removed without force. If it cannot, readjust gap.

5. To set air gap on run pick up of dual pick up distributors, first adjust start pick up as described in step 5, then adjust run pick up as describe in step

5. Use a 0.012 inch non-magnetic feeler gauge to adjust run pick up air gap.

6. Perform a second gap check using a 0.008 inch non-magnetic feeler gauge on all single pick up distributors and on start pick up of dual pick up 

distributor or a 0.014 inch non-magnetic feeler gauge on run pick up of dual pick up distributors. Do not force feeler gauge between reluctor tooth
and pick up pole as it is possible to do so. The feeler gauge should not be able to fit between the reluctor tooth and pick up pole if air gap is
correctly set. Apply vacuum to vacuum control unit (if equipped). Pick up should not contact reluctor tooth. Readjust air gap if contact occurs.

NOTE:  If pick up contacts reluctor teeth on one side of shaft only, the distributor shaft is most likely bent and shaft replacement required.

Relays and Modules - Ignition System > < Electrical Specifications|Page 1169