dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Recall - Oxygen Sensor & Cat Converter|Page 1133 > < Recall - Oxygen Sensor & Cat Converter|Page 1131
Page 3
background image

See Warranty Policy and Procedure Manual, Chapter 6, Subsection H for complete recall claim processing instructions.

PARTS RETURN

Removed catalytic converters must be returned to the Warranty Material Return Center.

Initially, a small number of oxygen sensors are required to be returned to the Warranty Material Return Center. When an adequate number of returned
parts have been accumulated, Parts Return Documents will no longer be generated and parts are to be discarded.

Note

See Warranty Policy and Procedure Manual, Chapter 6, Subsection H for complete recall claim processing and material return instructions.

Service Procedure

SERVICE PROCEDURE VIDEOTAPE

No videotape of the service procedure for this recall will be provided.

Service Procedure

A.

REPLACE OXYGEN SENSOR:

1.

Raise vehicle on hoist.

2.

Locate oxygen sensor in the exhaust "Y" pipe before the catalytic converter as shown in Figure 1.

3.

Disconnect oxygen sensor connector.

4.

Remove oxygen sensor.

5.

Clean threads in exhaust pipe with a thread chaser.

Note:

Do not use solvents or lubricants on threads.

6.

Install provided oxygen sensor. Tighten to 22 ft lbs (30 Nm).

7.

Connect oxygen sensor connector.

B.

REPLACE CATALYTIC CONVERTER:

Warning

If torches are used when working on the exhaust system, do not allow the flame near the plastic fuel lines.