Neon L4-2.0L SOHC (1995)
Shift Cable: Adjustments
1. Set parking brake, then remove floor console.
2. Place gear selector lever in (P) park position, then unsnap collar at shifter cable.
3. Move gear selector lever on transaxle to park position, then verify that both shifter lever and transaxle are in park position.
4. Rotate collar on shift cable adjuster until it seats against plastic housing, Fig.4. Collar must seat against plastic housing to achieve required detent
lock position.
5. Inspect adjustment as follows:
a. Detent position for neutral and drive should be within limits of hand lever gate stops.
b. Key start must occur only when shift lever is in neutral or park positions.