Fluid Pump: Description and Operation
NAG1 Automatic Transmission

Description

DESCRIPTION

The oil pump (2) (crescent-type pump) is installed in the bellhousing behind the torque converter and is driven by the drive flange of the torque
converter. The pump creates the oil pressure required for the hydraulic procedures.

Operation

OPERATION

When the engine is running, the oil  is pumped through the inlet chamber (5) along the upper and lower side of the crescent (1) to the pressure chamber
(6) of the housing. The meshing of the teeth prevents oil flowing from the delivery side to the intake side. An external gear (3) is eccentrically mounted
in the pump housing. The external gear is driven by the internal gear (4) which is connected to the torque converter hub.