dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Turn Signal Flasher|Locations|Page 8437 > < Turn Signal Flasher|Locations|Page 8435
Page 1
background image

Turn Signal Flasher: Description and Operation

DESCRIPTION

The combination flasher is a smart relay that functions as both the turn signal system and the hazard warning system flasher. The combination
flasher contains active electronic Integrated Circuitry (IC) elements. This flasher is designed to handle the current flow requirements of the
factory-installed lighting. If supplemental lighting is added to the turn signal lamp circuits, such as when towing a trailer with lights, the
combination flasher will automatically try to compensate to keep the flash rate the same.

While the combination flasher has a International Standards Organization (ISO)-type relay terminal configuration or footprint, the internal
circuitry is much different. The combination flasher does not use standard ISO-relay inputs or provide ISO-relay type outputs or functions. The
combination flasher should never be substituted for an ISO-relay or replaced with an ISO-relay, or else component and vehicle damage may occur.

Because of the active electronic elements within the combination flasher, it cannot be tested with conventional automotive electrical test
equipment. If the combination flasher is believed to be faulty, test the turn signal system and hazard warning system circuits. Then replace the
combination flasher with a known good unit to confirm system operation.

The combination flasher has five blade-type terminals intended for the following inputs and outputs: fused B(+), fused ignition switch output,
ground, turn signal circuit, and hazard warning circuit. Constant battery voltage and ground are supplied to the flasher so that it can perform the
hazard warning function, and ignition switched battery voltage is supplied for the turn signal function. 

The combination flasher is located in the junction block behind the fuse access panel on the left end of the instrument panel. The combination
flasher cannot be repaired or adjusted and, if faulty or damaged, it must be replaced.

OPERATION

Combination Flasher - Typical

The IC within the combination flasher contains the logic that controls the flasher operation and the flash rate. Pin 6 of the IC receives a sense
voltage from the hazard warning circuit of the multi-function switch. When the hazard warning switch is turned on, the "hazard on sense" voltage
will become low due to the circuit being grounded through the turn signal bulbs. This low voltage sense signals the IC to energize the flash control
Positive-Negative-Positive (PNP) transistor at a pre-calibrated flash rate or frequency. Each time the PNP transistor energizes the hazard warning
circuit, the pin 6 "hazard on sense" voltage will become high and the IC signals the PNP transistor to de-energize the circuit. This cycling will
continue until the hazard warning switch is turned off.

Likewise, pin 8 of the IC receives a sense voltage from the turn signal circuits of the multi-function switch. When the left or right turn signal
switch is turned on, the "turn signal on sense" voltage will become low due to the circuit being grounded through the turn signal bulbs. This low
voltage sense signals the IC to energize the flash control PNP transistor at a pre-calibrated flash rate or frequency Each time the PNP transistor
energizes the turn signal circuit, the pin 8 "turn signal on sense" voltage will become high and the IC signals the PNP transistor to de-energize the
circuit. This cycling will continue until the right or left turn signal switch is turned off.

A special design feature of the combination flasher allows it to "sense" that a turn signal circuit or bulb is not operating, and provide the driver an
indication of the condition by flashing the remaining bulbs in the affected circuit at a higher rate (120 flashes-per-minute or higher). Conventional
flashers either continue flashing at their typical rate (heavy-duty type), or discontinue flashing the affected circuit entirely (standard-duty type).
During turn signal operation, the combination flasher IC compares normal battery voltage input on pin 2 with the shunt resistor voltage input on
pin 7. If the IC "senses" that the voltage difference between pin 2 and pin 7 is different than the pre-calibrated value of the IC, it will increase the
rate at which it signals the PNP transistor to energize the pin 1 output. Thus, the inoperative half (left or right side) of the turn signal circuit will
flash faster.

Turn Signal Flasher|Locations|Page 8437 > < Turn Signal Flasher|Locations|Page 8435