dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Automatic Shut Down (ASD) Relay <--> [Main Relay (Computer/Fuel System)]|Locations|Page 2421 > < Automatic Shut Down (ASD) Relay <--> [Main Relay (Computer/Fuel System)]|Locations|Page 2419
Page 1
background image

Automatic Shut Down (ASD) Relay: Description and Operation

AUTO SHUTDOWN (ASD) RELAY

As one of its functions, the ASD relay will supply battery voltage to the ignition coil. The ground circuit for the ASD relay is controlled by the 
Powertrain Control Module (PCM). The PCM regulates ASD relay operation by switching the ground circuit on-and-off.

Power Distribution Center (PDC)

AUTOMATIC SHUTDOWN (ASD) RELAY SENSE-PCM INPUT

12 volt signal at this input indicates to the PCM that the ASD has been activated. The ASD relay is located in the Power Distribution Center
(PDC). The PDC is located in the engine compartment. Refer to label on PDC cover for relay location. The relay is used to connect the oxygen
sensor heater element(s), ignition coil(s) and fuel injectors to 12 volt + power supply.

This input is used to sense that the ASD relay is energized. If the powertrain control module (PCM) does not see 12 volts at this input when the 
ASD should be activated, it will set a Diagnostic Trouble Code (DTC).

Power Distribution Center (PDC)

AUTO SHUTDOWN (ASD) RELAY-PCM OUTPUT

The ASD relay is located in the Power Distribution Center (PDC).

The ASD supplies battery voltage to the fuel injectors, ignition coil and oxygen (O2S) sensor heating elements. The ground circuit for the coil in
the ASD relay is controlled by the powertrain control module (PCM). The PCM operates the relay by switching the ground circuit on and off.

Automatic Shut Down (ASD) Relay <--> [Main Relay (Computer/Fuel System)]|Locations|Page 2421 > < Automatic Shut Down (ASD) Relay <--> [Main Relay (Computer/Fuel System)]|Locations|Page 2419