Page 2
background image

Generator Connectors - Typical Denso

4. Remove upper generator mounting bolt and lower mounting bolt/nut.
5. Remove B+ terminal mounting nut at rear of generator. Disconnect terminal from generator.
6. Disconnect field wire connector at rear of generator by pushing on connector tab.
7. Remove generator from vehicle.

INSTALLATION

1. Position generator to engine and snap field wire connector into rear of generator.
2. Install B+ terminal to generator mounting stud. Tighten mounting nut to 8.5 Nm (75 in lbs) torque.
3. Install generator mounting fasteners and tighten as follows:

-

Generator mounting bolt - 41 Nm (30 ft lbs) torque.

-

Generator pivot bolt/nut - 41 Nm (30 ft lbs) torque.

CAUTION
-

Never force a belt over a pulley rim using a screwdriver. The synthetic fiber of the belt can be damaged.

-

When installing a serpentine accessory drive belt, the belt MUST be routed correctly. The water pump will be rotating in the wrong
direction if the belt is installed incorrectly, causing the engine to overheat. 

4. Install generator drive belt. 
5. Install negative battery cable(s) to battery(s).

Voltage Regulator > < Electrical Specifications|Page 5217